Repair orders dated on or after 8-16-2016 will be required to follow the new time amounts and require a RVC code.
Notice: There is no longer a cleaning procedure or replacement after attempting to clean the clutch assembly. Note this applies to 14M01 and TSB 16-0109. When replacing the clutch, the technician will now be required to provide a RVC code in order to get the claim paid by the OWS payment system.
I was just advised that if you complete 15B22 the customer will get a survey and most likely it be negative response so maybe do the reprograming within the TSB or M program instead. Use your judgement on these repairs.
Initial DIAG
14M01A or 160109A
perform TCM adaptive learn procedure.
Do not us with other ops. Focus, Fiesta 0.6 vs. 1.1
14M01B or 160109B
Perform PPT clutch shudder exceeds limits.
Enter RVC code. Focus,Fiesta 0.6 vs. 1.1
Labor claimed during to replace clutch only
14M01C or 160109C
Replace clutch includes reprogramming. Focus 5.2
Requires RVC code. Fiesta 4.7
14M01D or 160109D
Replace clutch and seals and reprogram. Focus 5.7
Requires RVC code. Fiesta 5.1